Influence of low Apgar on the first hearing screening of the neonate

Main Article Content

Daniela Polo Camargo da Silva
Georgea Espindola Ribeiro
Jair Cortez Montovani

Abstract

Introduction: There are several risk indicators for hearing loss. The Apgar score, when less than four in the first minute and/or less than six in the fifth minute of life, is considered an indicator of risk for hearing loss. Such values are associated with the occurrence of asphyxia, which is one of the most common causes of cell death and injury and, therefore, some damage to the auditory system may occur. Objective: To check the influence of risk indicator for hearing loss, low Apgar, in the first neonatal hearing evaluation. Methods: Cross-sectional study conducted in a public hospital from January 2012 to December 2016. The neonates underwent hearing evaluation by examining transient-evoked otoacoustic emissions (TEOAE). The relation between low Apgar and “refer” in the TEOAE was analyzed by simple logistic regression. Results: A total of 6,301 newborns were evaluated, of which 15.82% (n=996) had risk indicators for hearing loss and 6.57% (n=415) had with low Apgar. 6.5% (n=415) of the neonates screened showed failure of the EOE-t test, uni or bilateral. Others risk indicators increased the chances of “refer”; however, the presence of low Apgar alone increased the chances of “refer” in the TEOAE in newborns with birth weight greater than 1,500 g (OR: 1.58; p=0.02) and without peri-intraventricular hemorrhage (OR: 1.56; p=0.01). Conclusion: The low Apgar score was the mainly cause of “refer” on the first hearing evaluation among neonates with with birth weight greater than 1,500 g and without peri-intraventricular hemorrhage.

Downloads

Download data is not yet available.

Article Details

How to Cite
Silva, D. P. C. da, Ribeiro, G. E., & Montovani, J. C. (2019). Influence of low Apgar on the first hearing screening of the neonate. ABCS Health Sciences, 44(2). https://doi.org/10.7322/abcshs.v44i2.1183
Section
Original Articles
Author Biographies

Daniela Polo Camargo da Silva, Universidade Federal de Santa Catarina (UFSC) - Florianópolis (SC)

Departamento de Fonoaudiologia 

 

Georgea Espindola Ribeiro, Faculdade de Medicina, Universidade Estadual Paulista “Júlio de Mesquita Filho” (UNESP) – Botucatu (SP)

Departamento de Oftalmologia/Otorrinolaringologia e Cirurgia de Cabeça e Pescoço 

 

Jair Cortez Montovani, Faculdade de Medicina, Universidade Estadual Paulista “Júlio de Mesquita Filho” (UNESP) – Botucatu (SP)

Departamento de Oftalmologia/Otorrinolaringologia e Cirurgia de Cabeça e Pescoço 

 

References

Joint Committee on Infant Hearing. Year 2007 position statement: principles and guidelines for early hearing detection and intervention programs. Pediatrics. 2007; 120(4):898-921. http://dx.doi.org/10.1542/peds.2007-2333

Rai N, Thakur N. Universal screening of newborns to detect hearing impairment-is it necessary? Int J Pediatr Otorhinolaryngol. 2013;77(6):1036-41. http://dx.doi.org/10.1016/j.ijporl.2013.04.006

Alvarenga KF, Araújo ES, Melo TM, Martinez MAN, Bevilacqua MC. Questionnaire for monitoring auditory and language development in the first year. CoDAS. 2013;25(1):16-21. http://dx.doi.org/10.1590/S2317-17822013000100004

Lim HW, Kim EAR, Chung JW. Audiological follow-up results after newborn hearing screening program. Clin Exp Otorhinolaryngol. 2012;5(2):57-61. http://dx.doi.org/10.3342/ceo.2012.5.2.57

Amini E, Farahani ZK, Samani MR, Hamedi H, Zamini A, Yazdij AK, et al. Assessment of hearing loss by OAE in asphyxiated newborns. Iran Red Crescent Med J. 2014;16(1):e6812. https://doi.org/10.1055/s-0038-1648217

Lima MC, Rossi TR, Françozo Mde F, Collela-Santos MF, Correa CR. Analysis of neonatal hearing screening program performed on an outpatient basis: Analysis of an outpatient hearing screening program. Int J Pediatr Otorhinolaryngol. 2015;79(12):2227-33. http://doi.org/10.1016/j.ijporl.2015.10.009

Kiatchoosakun P, Suphadun W, Jirapradittha J, Yimtae K, Thanawirattananit P. Incidence and risk factors associated with hearing loss in high-risk neonates in Srinagarind Hospital. J Med Assoc Thai. 2012;95(1):52-7.

Cavalcanti HG, Melo LPF, Buarque LFSFP, Guerra RO. Overview of newborn hearing screening programs in Brazilian maternity hospitals. Braz J Otorhinolaryngol. 2014; 80: 346-353. http://dx.doi.org/10.1016/j.bjorl.2014.05.005

Wróbel MJ, Greczka G, Szyfter W. The risk factor profile of children covered by Polish universal neonatal hearing screening program and its impact on hearing loss incidence. Int J Pediatr Otorhinolaryngol. 2014;78(2):209-13. https://dx.doi.org/10.1016/j.ijporl.2013.10.052

Beswick R, Driscoll C, Kei J, Khan A, Glennon S. Which risk factors predict postnatal hearing loss in children? J Am Acad Audiol. 2013;24(3):205-13. https://dx.doi.org/10.3766/jaaa.24.3.6

Colella-Santos MF, Hein TAD, Souza GL, Amaral MIR, Casali RL. Newborn Hearing Screening and Early Diagnostic in the NICU. 2014; 2014:1-11. http://dx.doi.org/10.1155/2014/845308

Ribeiro GE, Silva DPC, Montovani JC. Transient evoked otoacoustic emissions and auditory brainstem response in infants with perinatal asphyxia. Int J Pediatr Otorhinolaryngol. 2016; 89:136-9. http://dx.doi.org/10.1016/j.ijporl.2016.08.009

Oliveira JS, Rodrigues LB, Aurélio FS, Silva VB. Risk factors and prevalence of newborn hearing loss in a private health care system of Porto Velho, Northern Brazil. Rev Paul Pediatr. 2013;31(3):299-305. http://dx.doi.org/10.1590/S0103-05822013000300005

Daniel SJ, Mcintosh M, Akinpelu OV, Rohlicek CV. Hearing outcome of early postnatal exposure to hypoxia in Sprague–Dawley rats. J Laryngol Otol. 2014;128(4):331-5. http://dx.doi.org/10.1017/S002221511300265X

Boskabadi H, Omidian M, Tavallai S, Mohammadi S, Parizadeh M, Mobarhan MG, et al. Serum Hsp70 antigen: early diagnosis marker in perinatal asphyxia. Iran J Pediatr. 2015;25(2):e381. http://dx.doi.org/10.5812/ijp.381

Medeiros TKS, Dobre M, Silva DMB, Brateanu A, Baltatu OC, Campos LA. Intrapartum fetal heart rate: a possible predictor of neonatal acidemia and APGAR Score. Front Physiol. 2018;9:1489. https://dx.doi.org/10.3389/fphys.2018.01489

Oliveira DC, Mandú ENT. Women with high-risk pregnancy: experiences and perceptions of needs and care. Esc Anna Nery. 2015; 19(1):93-101. http://dx.doi.org/10.5935/1414-8145.20150013

Silva DP, Lopez PS, Ribeiro GE, Luna MO, Lyra JC, Montovani JC. The importance of retesting the hearing screening as an indicator of the real early hearing disorder. Braz J Otorhinolaryngol. 2015; 81:363-7. http://dx.doi.org/10.1016/j.bjorl.2014.07.019

Januário GC, Lemos SMA, Friche AAL, Alves CRL. Quality indicators in a newborn hearing screening service. Braz J Otorhinolaryngol. 2015;81(3):255-63. http://dx.doi.org/10.1016/j.bjorl.2014.08.008

Maqbool M, Najar BA, Gattoo I, Chowdhary J. Screening for hearing impairment in high risk neonates: a hospital based study. J Clin Diagn Res. 2015;9(6):18-21. http://dx.doi.org/10.7860/JCDR/2015/14509.6104

Gouri ZUH, Sharma D, Berwal PK, Pandita A, Pawar S. Hearing impairment and its risk factors by newborn screening in north-western India. Matern Health Neonatol Perinatol. 2015;1:17. https://dx.doi.org/10.1186/s40748-015-0018-1

Regina M, Moideen SP, Mohan M, Mohammed MTP, Afroze KHM. Audiological screening of high risk infants and prevalence of risk factors. Int J Contemp Pediatr 2017;4(2):507-11. http://dx.doi.org/10.18203/2349-3291.ijcp20170699

Rodrigues PAL, Nardez TMB, Espindola MM, Gomes KCC, Silva BL. Comparison of two newborn hearing screening protocols with distinct reference criteria of distinct pass and failure. Rev CEFAC. 2016;18(4):876-80. http://dx.doi.org/10.1590/1982-021620161842816

Leite JN, Silva VS, Buzo BC. Otoacoustic emissions in newborns with mild and moderate perinatal hypoxia. Codas. 2016;28(2):93-8. http://dx.doi.org/10.1590/2317-1782/20162015086

Jiang ZD, Zang Z, Wilkinson AR. Cochlear function in 1-year-old term infants born with hypoxia-ischaemia or low Apgar scores. J Paediatr Child Health. 2012;48(2):160-5. http://dx.doi.org/10.1111/j.1440-1754.2011.02066.x

Lewis DR, Marone SAM, Mendes BCA, Cruz OLM, Nóbrega M. Comitê multiprofissional em saúde auditiva COMUSA. Braz J Otorhinolaryngol. 2010; 76(1):121-8. http://dx.doi.org/10.1590/S1808-86942010000100020